A manufacturer may be able to prepare pre-production documentation, but the available product details do not say that a sample report is included by default. They do list factory acceptance testing (FAT), routine and type tests, and a full inspection before shipment. Buyers should confirm in writing whether a report based on a production sample is available and define its contents before approving the technical drawings.

What the Product Information Confirms

  • The transformer is a three-phase, high-voltage dry-type model with epoxy resin cast or VPI construction and capacity ratings from 315 to 2500 kVA.
  • FAT, routine testing, type testing, and pre-shipment inspection are listed, but a pre-production sample report is not specifically mentioned.
  • Available parameters include high-voltage ratings of 11, 27, 33, and 40.5 kV, 0.4 kV low voltage, and AN or AF cooling.
  • Potential applications include data and computing centers, as well as industrial and commercial complexes.

Clarifying Testing and Reporting Requirements

A sample report is a distinct document and should not be assumed to be part of the stated inspection scope. The product details identify FAT, routine and type tests, and inspection before shipment, but do not specify whether a physical sample is provided, when any sample report would be issued, or which results it would contain.

During technical review, ask the manufacturer to confirm the report's availability, delivery schedule, test items, acceptance limits, format, and approval steps. The transformer information references IEC 60076-11 and GB/T 1094.11-2022, while the quality inspection entry refers to IEEE and IEC standards. Confirm which standards and records apply to the project in question.

Other stated design details include three-phase operation at 50 or 60 Hz, Dyn11 or Yyn0 vector groups, F-class insulation rated at 155 °C, and a tapping range of ±2 × 2.5%. The quoted delivery period is 45–60 working days after the deposit is received and technical drawings are confirmed. Agreeing on documentation before drawing approval helps establish the expected tests and deliverables.

Credentials and Project References

The company information lists UDEM certificate M.2052.206.C132155 for substations, transformers, and switchgear, as well as CNAS accreditation No. CNAS L16271 for testing an oil-immersed power transformer model. These credentials do not, by themselves, confirm that a pre-production report is supplied for this dry-type transformer.

Two cited projects demonstrate experience with other power-equipment work: a Madagascar grid renovation involving two 63/35 kV, 25 MVA units, and an indoor 110 kV GIS project in Suriname with 40 intervals. These references do not establish a reporting commitment for the product discussed here.

Documentation and Configuration at a Glance

ItemWhat is statedWhat to verify
Pre-production sample reportNo explicit commitment is givenAsk whether it can be issued, when it will be available, and what it covers
Factory acceptance testingFAT is included in the listed inspection provisionsConfirm the test scope and whether results are provided in a report
Routine and type testingBoth test categories are listedAgree on applicable tests and acceptance criteria
Pre-shipment inspectionA full inspection before shipment is statedConfirm which inspection records accompany the shipment
Transformer configurationThree phase, 315–2500 kVA, with high-voltage options from 11 to 40.5 kVVerify project ratings and the approved drawings

Frequently Asked Questions

Is a pre-production sample report guaranteed?

No. The product information mentions FAT, routine and type testing, and inspection before shipment, but does not expressly promise a pre-production sample report.

Which test records should buyers request?

Ask which FAT, routine-test, and type-test results can be documented, when the records will be issued, and whether they cover the approved transformer design and the standards agreed for the project.

When should reporting details be settled?

Confirm the requirements during the technical review and before approving the drawings. The stated lead time starts after the deposit and technical drawing confirmation.

Conclusion

The manufacturer lists several testing and inspection activities, but the available details do not confirm that a pre-production sample report comes as standard. Obtain written agreement on whether the report can be provided and what it will contain, alongside the FAT, routine-test, type-test, and shipment-inspection requirements. Supply options include manufacturer, OEM and ODM, and turnkey project services; the minimum order quantity is one. The listed lead time is 45–60 working days after deposit and drawing confirmation. For technical questions, contact support@vziman.com.

About the Company

Zhejiang Vziman Electric Power Technology Co., Ltd. is the parent company of Zhejiang Vziman Electric Group Co., Ltd. The group focuses on research and development, manufacturing, and service for electrical power equipment, including transformers and switchgear. Its company profile reports a 10,000-square-meter factory and an R&D team of more than 30 senior electrical engineers and industrial designers. Listed credentials include UDEM and CNAS, and its project references include utility and transmission-grid work.

Zhejiang Vziman Electric Power Technology Co., Ltd. logo

REPORT

Code
Choose a different language
Current language: