When specifying an Extra High Voltage (EHV) transformer, confirm both its rated voltage and the insulation withstand values required by the project. The available product data identifies a 330 kV rated voltage and operation at 50/60 Hz, but it does not give lightning impulse or power-frequency withstand levels. These values must be checked against the applicable grid and project specifications before equipment selection.
Start by matching the transformer's insulation requirements to the system voltage and the project's technical specification. While the product information states a rated voltage of 330 kV, the model designation refers to 345 kV and 363 kV as well. No corresponding withstand values are provided for these voltage references, so their meaning should be clarified with the supplier.
Before technical approval, ask for the insulation schedule along with the relevant routine-test and type-test records. The listing says that factory acceptance testing (FAT), routine tests, type tests, and a full inspection before shipment are available. It also states compliance with IEEE and IEC standards, but does not identify standard editions or test values. Confirm the applicable editions, scope, and documentation for the order.
The company profile mentions UDEM certification for substations, transformers, and switchgear, and a CNAS-accredited test result for a particular oil-immersed transformer model. These credentials may provide supporting information, but they do not replace any certification required by local regulations. The cited project references also do not establish EHV insulation values: one Madagascar grid renovation used two 25 MVA, 63/35 kV transformers, and a Suriname transmission project included 40 intervals of 110 kV indoor GIS.
The product listing includes a factory image of the intelligent EHV transformer.
| Specification | Information provided | What to verify |
|---|---|---|
| Rated voltage | 330 kV | Check the required system voltage and clarify the 345 kV and 363 kV references in the model name. |
| Insulation withstand | Values are not listed | Request the specified withstand levels and associated test requirements. |
| Frequency and capacity | 50/60 Hz; 15,000 kVA | Confirm both values meet the project specification. |
| Testing and standards | FAT, routine and type testing, and pre-shipment inspection are listed; IEEE and IEC compliance is stated. | Agree on standard editions, test scope, and deliverable records for the order. |
Does the product information include a lightning impulse withstand value?
No. It lists rated voltage, frequency, and capacity, but does not provide an impulse withstand level.
Are 345 kV and 363 kV confirmed rated voltages?
Those figures appear in the model name. The parameter information specifies 330 kV as the rated voltage and does not clarify the other figures.
What documents should be requested before approving an EHV transformer?
Request the project-specific insulation schedule, the applicable standards and editions, and relevant test records. The listing indicates that FAT, routine testing, type testing, and pre-shipment inspection are available.
The available specifications identify a 330 kV intelligent EHV transformer, but leave its insulation withstand levels unstated. Treat those levels as project requirements and obtain written confirmation from the supplier before technical approval. Zhejiang Vziman Electric Power Technology Co., Ltd. describes its business as power-equipment research and development, manufacturing, and service, with manufacturing, OEM/ODM, and turnkey project supply among its business models. Technical inquiries can be sent to support@vziman.com.
Zhejiang Vziman Electric Power Technology Co., Ltd. is the parent company of Zhejiang Vziman Electric Group Co., Ltd. The group develops, manufactures, and services electrical equipment for grid construction, renewable energy, and industrial distribution. Its profile lists a research and development team of more than 30 senior electrical engineers and industrial designers, with products including power transformers, prefabricated substations, and medium- and high-voltage switchgear. The profile also cites UDEM and CNAS credentials and experience in utility power and transmission projects.

REPORT