Choosing a dry type transformer for data center backup power starts with the facility’s load schedule and electrical design. The transformer must match the required capacity, voltage, frequency, connection, cooling, and insulation specifications while fitting the planned redundancy arrangement. The listed three-phase model is available from 500 to 2,500 kVA, with customized ratings offered. Confirm the final configuration through project calculations and approved technical drawings before ordering.
Identify the equipment the transformer will serve during a backup event, then review the documented demand alongside the data center’s power distribution and redundancy configuration. The required transformer rating depends on that project-specific arrangement.
The listed capacity range is 500–2,500 kVA, and customized capacity is available. The product information does not provide a sizing formula or a specified overload capability. Use the project’s electrical calculations and supplier drawings to confirm the selected rating.
For data and computing centers, the company identifies reliable power supply, redundant configurations, and strict monitoring as key application requirements. These needs should be reflected in the overall system design and equipment specification.
Listed voltage options are 6, 11, 13.8, 15, and 20 kV, with customized types also available. The transformer is specified for three-phase operation at either 50 Hz or 60 Hz. Check the required primary and secondary characteristics against the site design and confirm them in the technical drawings.
Dyn11 and Yyn11 vector groups are listed. Review the selected connection with the project’s grounding, protection, and distribution requirements. The standard tap arrangement is ±2 × 2.5%; an on-load tap changer (OLTC) is offered as an option.
Available cooling modes are AN and AF, and the listed insulation classes are F and H. Select these features according to the installation conditions and project design. The stated insulation level is LI/AC-125/50 kV; verify its suitability for the specified equipment and application.
The product information does not provide an acoustic performance value. If the installation has a noise limit, request the relevant data and confirm the requirement before finalizing the order.
| Selection factor | Listed specification | Project review |
|---|---|---|
| Rated capacity | 500–2,500 kVA or customized | Confirm the rating against calculated backup demand and redundancy configuration |
| Voltage and frequency | 6, 11, 13.8, 15, or 20 kV; 50 or 60 Hz; customized voltage types available | Verify compatibility with the facility’s electrical design |
| Cooling and insulation | AN or AF cooling; insulation class F or H | Check installation conditions and specified insulation requirements |
| Connections and taps | Dyn11 or Yyn11; ±2 × 2.5% standard taps or optional OLTC | Review the vector group, voltage adjustment, grounding, and protection design |
| Inspection and delivery | FAT, routine testing, type testing, and pre-shipment inspection; 45–60 working days after deposit and drawing confirmation | Agree on the applicable test scope and confirm the schedule after technical approval |
The product information lists IEC, IEEE, ANSI, GOST, NEMA, CE, and ISO among its standards and references. It describes factory acceptance testing (FAT), routine and type testing, and full inspection before shipment, with compliance stated for IEEE and IEC. Agree with the supplier on the standards and tests applicable to the specific order.
Company records also list UDEM certification covering substations, transformers, and switchgear, as well as CNAS accreditation for testing an oil-immersed transformer model. The CNAS document provides technical support; it does not replace certification required by local authorities or establish certification of this dry type model.
The company reports a Madagascar utility project involving two 25 MVA, 63/35 kV power transformers for a substation renovation. That project is separate from the dry type transformer described here and does not establish this model’s performance.
Determine the rating from the backup load calculation and planned power configuration. The listed product range is 500–2,500 kVA, with customized capacities available; the source does not state an overload rating.
The listed voltage options are 6, 11, 13.8, 15, and 20 kV, with customized types available. Frequency options are 50 Hz and 60 Hz. Confirm the required values in the approved drawings.
The listing includes FAT, routine and type tests, and inspection before shipment. It also states a 72-hour global technical response, on-site commissioning and training, spare-parts supply, and remote diagnostics. Confirm the applicable test and service scope with the supplier.
Before placing an order, align the load calculations, electrical connections, cooling method, insulation class, taps, and inspection requirements with the supplier’s technical drawings. The stated lead time is 45–60 working days after deposit and drawing confirmation. Vziman lists manufacturer, OEM and ODM, and turnkey project supply models. For technical solutions or support, contact support@vziman.com.
Zhejiang Vziman Electric Power Technology Co., Ltd. is the parent company of Zhejiang Vziman Electric Group Co., Ltd. The group’s predecessor companies trace back to Zhejiang Powertech Electric Co., Ltd., founded in 2014. It develops, manufactures, and services electrical power equipment, including transformers, switchgear, distribution equipment, and power automation systems.
The company states that its research and development team includes more than 30 senior electrical engineers and industrial designers and that its markets span over 100 countries. It lists UDEM and CNAS-related credentials and reports utility projects in Madagascar, the Dominican Republic, and Suriname.