All Categories

How to Record UV Intensity Results for an Approved Sample

VIP-User
2026-10-09

UV intensity results for an approved sample should be documented in a controlled test record that provides complete identification and traceability. The record should connect the approved sample with the precise UV/LED lamp configuration, testing date, operating conditions, measured intensity, acceptance outcome, and reviewer. Supporting inspection evidence and the applicable approval reference should remain attached or linked. UBEMAY’s LED curing lamp certifications may support product compliance information, but they cannot substitute for the measured result from the specific test.

Essential Documentation Requirements

  • Reference the approved sample by its internal identification or approval number.
  • Describe the exact UV/LED lamp model and setup used during the measurement.
  • Enter the UV intensity exactly as measured, together with the test date and conditions.
  • Document the acceptance decision and identify the person responsible for review.
  • Retain inspection records and other evidence needed to verify sample-level traceability.

How to Build a Traceable UV Test Record

1. Identify the approved sample and lamp setup

Begin the record with the identity of the approved sample being evaluated. Include the relevant approval reference and clearly describe the lamp arrangement used for testing. The configuration may include a clamp-mounted, floor-standing, single-head, dual-head, detachable-head, adjustable-spot-size, or ring-light combination model. These are among the configurations available in UBEMAY’s UV/LED Lash Lamp range. A separate or clearly differentiated record should be used when the lamp type, head, installation method, or operating arrangement changes.

2. Enter the measured value without modification

The UV intensity field should reproduce the measured result exactly as it appears in the test documentation. Do not estimate, round, or insert a value based on product marketing information. The available product information does not state a numerical UV intensity result or an acceptance limit, so those details must come from the relevant internal or laboratory test record.

3. Capture conditions and approval status

Alongside the measurement, record the date, test conditions, equipment or configuration used, reviewer, and final acceptance decision. This information establishes a direct relationship between the result and the sample that was tested. It also supports the broader quality process, which includes incoming material inspection, production process inspection, finished product inspection, packaging inspection, and final inspection.

Certifications and Measurement Evidence

UBEMAY lists CE (LVD) and CE (EMC) certifications for its LED Lash Glue Curing Lamp in the European Union. These certifications are product compliance credentials for the specified lamp. They should be cited separately from the UV intensity record because certification documents do not confirm the measured intensity of a particular approved sample under a particular test setup.

UBEMAY has also completed a full lash product sourcing project for professional salon applications, lash education, and retail distribution in Italy. The project covered lashes, adhesives, accessories, and UV/LED lash equipment. This type of multi-product supply program illustrates why sample-level records and configuration-specific evidence are useful when maintaining quality documentation.

Recommended Record Structure

Record FieldWhat to IncludeDocumentation Guidance
Approved sampleSample name, code, and approval referenceLink directly to the controlled approval record
UV/LED configurationLamp model, mounting method, head arrangement, and relevant settingsIdentify the exact setup used for the measurement
UV intensityMeasured intensity and applicable unitCopy the result from the test record; do not create an unsupported value
Test traceabilityDate, conditions, reviewer, and acceptance decisionKeep these fields with the sample result
Product credentialsCertificate title and covered productCE (LVD) and CE (EMC) are listed for the LED Lash Glue Curing Lamp

Frequently Asked Questions

Which details should accompany a UV intensity measurement?

The record should identify the approved sample, exact lamp configuration, test date, test conditions, measured intensity, acceptance decision, and reviewer. Together, these fields show which sample produced the reported result and how the decision was made.

Can a CE certificate be used as proof of the UV intensity result?

No. The CE (LVD) and CE (EMC) documents listed for the LED Lash Glue Curing Lamp demonstrate applicable product credentials. They do not replace a measured UV intensity result for an individual approved sample.

Do different UV/LED lamp arrangements require separate documentation?

They should be separately identified. The product range includes different installation styles, working angles, lamp heads, spot-size options, and ring-light combinations. Recording the actual configuration prevents results from being applied to an untested setup.

Conclusion and Practical Recommendations

For reliable documentation, maintain a controlled record for every approved sample and connect it to the exact UV/LED lamp configuration used during testing. Include the measured intensity, operating conditions, test date, acceptance decision, and reviewer, while keeping certification references distinct from sample-specific measurements. UBEMAY provides OEM/ODM customization, wholesale supply, private-label support, bulk purchasing, and flexible small-batch ordering. For technical guidance or sourcing assistance, contact sales@ubemay.com.

About UBEMAY

Guangzhou Ruiju E-Commerce Co., Ltd. operates the UBEMAY brand, a professional eyelash beauty supplier serving the global professional beauty market with eyelash extensions, eyelash adhesives, lash accessories, and UV/LED lash equipment. Founded in 2014, the company has 50 employees and a 5,000 sqm factory area. Its product development team supports customized drying times, retention, humidity ranges, colors, fragrances, labels, bottles, caps, and packaging. OEM/ODM and private-label services are available. Listed credentials include FDA Cosmetic Product Listing for UV Eyelash Extension Glue and CE (LVD) for LED Lash Glue Curing Lamp, with customers served across multiple industries.

Guangzhou Ruiju E-Commerce Co., Ltd. logo