Thermal test documentation is an important part of approving a dry type transformer for data center service. The available information for the low-noise epoxy resin indoor dry type transformer confirms a broad quality-control program, including factory acceptance testing, routine tests, type tests, and inspection before shipment. However, it does not include actual temperature-rise values or a dedicated thermal test report. These records should be requested together with the technical drawing and inspection documents.
This indoor transformer uses epoxy resin insulation and is available in capacities from 500KVA to 2500KVA, with customized ratings available when required. The standard tap range is ±2x2.5%, and an OLTC option can also be specified. Available vector groups include Dyn11 and Yyn11.
Thermal suitability must be checked against the transformer capacity, selected cooling method, insulation class, voltage level, and actual data center loading profile. Although the product information identifies AN and AF cooling, it does not state temperature-rise limits, loss values, thermal curves, test duration, ambient conditions, or measured winding temperatures. Approval should therefore remain conditional until the manufacturer provides the relevant thermal evidence.
For a complete technical evaluation, request the thermal test report, temperature-rise results, test conditions, rated-load information, loss measurements, cooling configuration, and the drawing corresponding to the quoted unit. The documents should identify the applicable IEC or IEEE requirements and confirm that the tested configuration matches the proposed transformer.
The stated inspection program includes factory acceptance testing, routine tests, type tests, and full inspection before delivery. Compliance with IEEE and IEC standards is indicated in the product information. The company profile also references CE, ISO, ANSI, GOST, and NEMA requirements, as well as UDEM certification for substations, transformers, and switchgear. CNAS accreditation is associated with an oil-immersed power transformer model.
The manufacturer has also reported experience on a 110kV indoor GIS project for a national power company in Suriname. That customized GIS project included local grid compliance and on-site commissioning support. Because the project involved GIS rather than the epoxy resin dry type transformer described here, it should be considered general company experience rather than direct evidence of this product's thermal performance.
| Evaluation Category | Information Currently Available |
|---|---|
| Thermal verification | No specific thermal report, temperature-rise figures, or thermal curves are included; the applicable records should be requested. |
| Factory testing | FAT, routine testing, type testing, and complete inspection before shipment are identified. |
| Cooling options | Natural air cooling (AN) and forced air cooling (AF) are available. |
| Electrical configuration | Three-phase construction, Class F or H insulation, and 50Hz or 60Hz frequency. |
| Capacity and voltage range | 500KVA to 2500KVA and 6KV to 20KV, with customized configurations supported. |
| Referenced standards | IEEE and IEC compliance is stated, with additional CE, ISO, ANSI, GOST, and NEMA references. |
No. It describes the general testing and inspection program but does not provide a thermal test certificate, temperature-rise data, or measured thermal performance.
Verify the rated voltage, capacity, frequency, tap arrangement, cooling mode, insulation class, vector group, loading conditions, and required IEC or IEEE standard. These details determine whether the thermal report applies to the proposed data center installation.
The listed services include a global technical response within 72 hours, on-site commissioning and training, spare-parts support, and remote diagnosis. The company also provides manufacturing, OEM and ODM, and turnkey project services.
The available information demonstrates a defined manufacturing and inspection process, along with flexible cooling, insulation, voltage, and capacity options for data center applications. It does not, however, verify the thermal behavior of a specific transformer. Before approval, obtain the thermal test report, temperature-rise limits, test conditions, loss data, and matching technical drawing. FAT witnessing, third-party inspection, and pre-shipment review can also be arranged. For technical assistance, contact support@vziman.com.
Zhejiang Vziman Electric Power Technology Co., Ltd. is a high-tech company focused on the research, production, and service of electrical equipment for grid construction, renewable energy, and industrial distribution. Its team includes more than 30 senior electrical engineers and industrial designers, supported by testing equipment and automated manufacturing lines for customized power solutions. Its product range includes power transformers, earthing transformers, distribution transformers, prefabricated substations, feeder switchboards, and medium- and high-voltage switchgear. The company holds UDEM certification and serves customers in several industrial sectors.

REPORT